What the Building Safety Act's 'Golden Thread' Means for Fire-Rated Partition Specification

The Building Safety Act introduced a requirement known as the golden thread of information. This is a required digital record that has to be kept accurate and handed on as a building moves from design through construction and into occupation. Approved Document B already sets out the fire separation standards a building has to meet. The golden thread adds a second requirement on top of that. It isn't enough to meet the standard once, at the design stage. There has to be an accurate, accessible record proving the standard was actually met, and that it still holds true years later. For fire-rated partitions and glazing, that means the specification data behind every system needs to be correct from the outset and kept that way for as long as the building stands.
Specification records under new scrutiny
This isn't limited to one product category. Amendments to Approved Document B are already reshaping drainage specification on high-rise schemes, pushing non-combustible performance requirements further into material choices that used to get less scrutiny. Fire-rated partitions and glazing sit squarely inside that same shift. Every system specified has to carry a record that can stand up to a building control check years after installation, not just at the point of sign-off.
Where fire rating terminology goes wrong
Part of the problem is that fire rating terminology gets misapplied more often than it should. A similar mix-up has been reported in fire-rated storage, where products are mislabelled and specifiers end up relying on the wrong test standard without realising it. The same risk applies to partitions and glazing. A rating that sounds right on a spec sheet is only useful if it's the correct rating for that product type, tested to the right standard and classified the right way. Get that wrong and the golden thread record is inaccurate before the building has even opened.
Matching the fire rating to the product
Steel-framed and glazed fire-rated systems are a common place for this to happen. Legacy designations such as FD30 or FD60 were developed for timber fire doors, and applying them to steel or glazed systems isn't accurate. The fix is to use the test standard and rating system that actually applies to the product type being specified. Technical guidance on E and Ei fire door ratings, published by Radii Planet Group, makes this point directly, explaining that steel-framed glazed systems are tested under European standard EN 1634-1 and classified under EN 13501-2. It warns separately that using an FD rating for these products instead, "can create confusion in certification, regulatory approval, or building control processes."
E measures how long a system blocks flame and hot gases, while Ei adds a thermal limit, recommended for escape routes such as corridors and stairwells where people need to pass safely. Specifying the correct classification, rather than a familiar but mismatched one, is what keeps the record behind the product accurate.
Keeping the ‘golden thread’ accurate over time
Achieving the right classification at specification stage is only the start. The golden thread has to be created before work begins, handed to the accountable person on completion, and kept accurate and accessible for as long as the building is occupied. That means any later change, a refurbishment, a reconfiguration, or a replacement part, needs to be checked against the same classification and recorded the same way. A record that was correct on day one but never gets updated is no longer doing its job.
What this means for specifiers
None of this is about one product being better than another. It's about making sure the classification on paper matches the system that's actually installed, using the right test standard, and keeping that record current as the building changes. For a specifier working on a scheme now, that means checking that the rating on a data sheet actually applies to the product type being installed. It means not simply carrying over a familiar label from a different kind of system out of habit, just because it has always been used before.